CTA Flexible Current Transformers

CTA Current Output Flexible Sensor
with 1A or 5A outputs
5VA rated output drives long cable runs up to 50ft/15.2m
CTA3ph 0-5A output "Rope Type" Flexible Current Sensor Specifications
The Powertek CTA3ph flexible sensor & conditioning module are supplied as calibrated sets with a traceable calibrated 0-5Arms output. In addition, these modules can be configured to convert any voltage output current measuring device to a 1A or 5A secondary.
​
Current Sense coil
-
Diameters: 100mm/3.85", 160mm/6.2”, 220mm/8.6”, 330mm/11.7" clip-around sensor,
-
Split core / wrap-around construction
-
Sensor Thickness: 8mm/0.31"
-
Material: Flexible Thermoplastic rubber, flame retardant UL94V0
-
Working voltage: 1000V at 50/60Hz CAT III, tested 7400V 50/60Hz 1 minute
Cable
-
1000V UL style 20940, 5mm dia, 3m, 5m and 10m lengths
Conditioner-amplifier
-
Input ranges: From 0-100A to 0-10,000Arms
-
Accuracy class options, 10%-100% range: <0.25%, <0.5%, <1.0%
-
Casing: Din Rail module UL94V0 and CSA approved polycarb
-
Fundamental Frequency: 20Hz to 500Hz
-
Bandwidth: 20Hz-500Hz CTA3ph 5A
-
Output ratings: 2.5VA (0.1ohm burden), 5VA (0.2ohm burden) or 7.5VA
-
Phase shift: <0.04° at 50/60/400Hz
-
Input impedance: 100kohm
-
Accurate with waveform crest factors: 1.4 - 5
-
Health monitoring LEDs and fault reporting relay outputs
-
Power: 110Vac-240Vac power, optional 24Vdc, 48Vdc and 125Vdc
-
Fuse for 230/240Vac instrument power 1A slow blow or time delay
-
Includes: Din Rail, PSUs, conditioner and output transformer (5A)
Environmental
-
Operational range -20°C to +65°C
All products have CE, IEC, EN, ASME or BS approvals
Downloads
Assembly Dimentions

Standard 5VA Models to 1500A
​
-
CTA3ph/100/5A/5/160
-
CTA3ph/200/5A/5/160
-
CTA3ph/300/5A/5/160
-
CTA3ph/400/5A/5/160
-
CTA3ph/500/5A/5/160
-
CTA3ph/600/5A/5/160
-
CTA3ph/700/5A/5/160
-
CTA3ph/800/5A/5/160
-
CTA3ph/1000/5A/5/160
-
CTA3ph/1200/5A/5/160
-
CTA3ph/1500/5A/5/160
Standard 5VA Models to 10,000A
​
-
CTA3ph/1600/5A/5/160
-
CTA3ph/2000/5A/5/160
-
CTA3ph/2500/5A/5/160
-
CTA3ph/3000/5A/5/160
-
CTA3ph/3500/5A/5/160
-
CTA3ph/4000/5A/5/160
-
CTA3ph/5000/5A/5/160
-
CTA3ph/6000/5A/5/160
-
CTA3ph/7000/5A/5/160
-
CTA3ph/8000/5A/5/160
-
CTA3ph/10000/5A//160
-
Kit includes 3x current sensors, cables, conditioners, psus, Din-Rail
-
Wired and ready to use
-
Flexible Three Phase Rogowski AC current sensor
-
Uses Flexible Core 5A output Rogowski Coil sensing technology, UV resistant models
-
Compact high accuracy sensors from 1% to 125% of range
-
Flexible AC Current Sensors will fit in tight spaces
-
Split core clip-together AC sensing probes for fast installs
-
Quick fitting capability allows for live installs or short shutdown period
-
Available ratings 2.5VA, 5VA or 7.5VA
-
Options for long 'sensor to metering' distances
-
Relay contacts for health reporting
The CTA3ph Three Phase flexible current transformers are the world's first flexible 'clip-on' current probe with a 5A 5VA output, allowing compatibility with existing 5A metering circuits. Unlike conventional CTs, there are no open circuit hazards - ideal for retrospective metering projects and installations in confined spaces where installation of conventional iron core CTs is not possible. The CTA3ph 5A output Rogowski Coil current sensing, simplifies installation and eliminates the need for expensive LV/HV plant shutdowns. In addition, the CTA modules can be used to convert any voltage output current measuring device to a 1A or 5A secondary.
​
The CTA3ph flexible current transformers convert AC current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring, including Data Centres, Hospitals, Banks, Shopping Centres where Energy Management, power, energy and current monitoring is crucial. For all CTA3ph three phase current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA3ph sensors use UL94V0 or CSA approved materials. The CTA3ph flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable - even in confined spaces. The 5A output from the CTA3ph current sensor connects direct to installed metering, rotary metering or current transducers.
CTA 3ph 0-5A Rogowski Coil facts and important application information
-
Uses the latest 5A output Rogowski Coil current sensing technology
-
Suitable for three phase systems in Data Centres, Shopping Centres, Banks
-
Available sense coil diameters 100mm, 150mm, 200mm and 330mm
-
Isolated measurement outputs interface easily to kWHr metering
-
5Arms metering compatible output at 2.5VA, 5VA or 7.5VA
-
1kV insulation continuous (tested 7.4kV)
-
Available as 0.25%, 0.5%, and 1% accuracy class
-
Long distance option 0-5A; Up to 500m (1640ft)
-
Wide measurement range from 1% to 125% of range
-
Flat frequency response from 25Hz to 500Hz
-
110Vac-240Vac power supply, optional 24Vdc, 48Vdc or 125Vdc
-
Operating range -20°C to +45°C, sensors +80°C
-
Safety EN61010-1 1000Vac CATIII, 600Vac CATIV CE marked, UL94V0 flame retardant
-
Options for Energy Monitoring and Power Quality Analysis
-
Allows fast installation, supervised live installs
-
Accreditation certificate and calibration data
-
Fast installs are possible in Data Centres, Airports, Shopping Centres and Banks
-
Ideal for Current sensing in Active Harmonic Filters where burden can exceed 5VA
-
Install without shutting down the LV electrical supply, avoiding expensive down-time costs
-
Retrospective energy monitoring include hospitals, shopping centres, server farms, marine/shipping
-
Allowing compatibility between Energy Management Systems and older legacy metering
-
Power, energy and current monitoring on renewables
-
Fast response feedback signal for active harmonic cancellation and filters
-
The CTA3ph flexible current sensors are suited to permanent or semi permanent installation
-
The coil sensor is durable, lightweight, flexible and will easily clip-around a busbar or 3ph feeder
-
Suited to installations where conventional CTs are physically too large